Roper Technologies image pro analyser 3d software, was used to automatically extract the centerline of the vessel tree
Overview and quantification of the <t>3D</t> morphology of the rat spinal cord microvasculature. (A–C) The raw image of the spinal cord microvasculature among cervical, thoracic, and lumbar regions. (D–F) Representative images of the <t>segmented</t> <t>vasculature</t> and the color-coded labeled vessels of the spinal cord among the three regions. The major arteries and veins including the posterior spinal artery (PSA), central sulcus artery (CSA), anterior spinal artery (ASA), and the posterior spinal vein (PSV). (G–I) The pseudocolored image of the spinal cord microvasculature among three regions. The color bar on the left of the panel indicates the associated vessel diameters. The smallest capillaries are depicted in red and the largest vessels in blue. (J–N) The mean vessel volume fraction, vessel thickness, segment density, bifurcation density, and segment length were relatively lower in the thoracic region than the cervical and lumbar spinal cord; * p < 0.05. (O) Vessel distribution histogram revealed the vessel thickness in the thoracic region with a diameter of less than 25 μm was slightly lower than that of the cervical and lumbar regions. C, cervical spinal cord; T, thoracic spinal cord; L, lumbar spinal cord. * p < 0.05. Scale bar = 200 μm.
Image Pro Analyser 3d Software, Was Used To Automatically Extract The Centerline Of The Vessel Tree, supplied by Roper Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/image+pro+analyser+3d+software++was+used+to+automatically+extract+the+centerline+of+the+vessel+tree/pmc07387706-47-65-18
Average 90 stars, based on 1 article reviews
image pro analyser 3d software, was used to automatically extract the centerline of the vessel tree - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
FUJIFILM 3d image analysis system volume analyser synapse vincentr
Overview and quantification of the <t>3D</t> morphology of the rat spinal cord microvasculature. (A–C) The raw image of the spinal cord microvasculature among cervical, thoracic, and lumbar regions. (D–F) Representative images of the <t>segmented</t> <t>vasculature</t> and the color-coded labeled vessels of the spinal cord among the three regions. The major arteries and veins including the posterior spinal artery (PSA), central sulcus artery (CSA), anterior spinal artery (ASA), and the posterior spinal vein (PSV). (G–I) The pseudocolored image of the spinal cord microvasculature among three regions. The color bar on the left of the panel indicates the associated vessel diameters. The smallest capillaries are depicted in red and the largest vessels in blue. (J–N) The mean vessel volume fraction, vessel thickness, segment density, bifurcation density, and segment length were relatively lower in the thoracic region than the cervical and lumbar spinal cord; * p < 0.05. (O) Vessel distribution histogram revealed the vessel thickness in the thoracic region with a diameter of less than 25 μm was slightly lower than that of the cervical and lumbar regions. C, cervical spinal cord; T, thoracic spinal cord; L, lumbar spinal cord. * p < 0.05. Scale bar = 200 μm.
3d Image Analysis System Volume Analyser Synapse Vincentr, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/3d+image+analysis+system+volume+analyser+synapse+vincentr/pmc10284686-48-14-17
Average 90 stars, based on 1 article reviews
3d image analysis system volume analyser synapse vincentr - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Roper Technologies image pro analyser 3d software
Schematic depiction of a randomly selected vessel within the intact spinal cord for <t>3D</t> quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The <t>corresponding</t> <t>2D</t> virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.
Image Pro Analyser 3d Software, supplied by Roper Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/image+pro+analyser+3d+software/pmc07387706-39-8-15
Average 90 stars, based on 1 article reviews
image pro analyser 3d software - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
LemnaTec Inc 3d image analyser
Schematic depiction of a randomly selected vessel within the intact spinal cord for <t>3D</t> quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The <t>corresponding</t> <t>2D</t> virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.
3d Image Analyser, supplied by LemnaTec Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/3d+image+analyser/pmc03042986-110-4-7
Average 90 stars, based on 1 article reviews
3d image analyser - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
FUJIFILM 3d image analysis system volume analyser synapse vincentsr
Schematic depiction of a randomly selected vessel within the intact spinal cord for <t>3D</t> quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The <t>corresponding</t> <t>2D</t> virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.
3d Image Analysis System Volume Analyser Synapse Vincentsr, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/3d+image+analysis+system+volume+analyser+synapse+vincentsr/pm37307071-39-14-18
Average 90 stars, based on 1 article reviews
3d image analysis system volume analyser synapse vincentsr - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Ratoc Systems Inc 3-dimensional analysis try/3d bon
Schematic depiction of a randomly selected vessel within the intact spinal cord for <t>3D</t> quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The <t>corresponding</t> <t>2D</t> virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.
3 Dimensional Analysis Try/3d Bon, supplied by Ratoc Systems Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/imaging+analyser+try+3d+srfii/pmc03401028-56-11-17
Average 90 stars, based on 1 article reviews
3-dimensional analysis try/3d bon - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Quantificare Inc 3d imaging systems for skin macro- and micro-structure analyses lifeviz mini
Schematic depiction of a randomly selected vessel within the intact spinal cord for <t>3D</t> quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The <t>corresponding</t> <t>2D</t> virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.
3d Imaging Systems For Skin Macro And Micro Structure Analyses Lifeviz Mini, supplied by Quantificare Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/3d+images+analyses/3d+imaging+systems+for+skin+macro++and+micro+structure+analyses+lifeviz+mini/pm33048421-71-24-33
Average 90 stars, based on 1 article reviews
3d imaging systems for skin macro- and micro-structure analyses lifeviz mini - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Overview and quantification of the 3D morphology of the rat spinal cord microvasculature. (A–C) The raw image of the spinal cord microvasculature among cervical, thoracic, and lumbar regions. (D–F) Representative images of the segmented vasculature and the color-coded labeled vessels of the spinal cord among the three regions. The major arteries and veins including the posterior spinal artery (PSA), central sulcus artery (CSA), anterior spinal artery (ASA), and the posterior spinal vein (PSV). (G–I) The pseudocolored image of the spinal cord microvasculature among three regions. The color bar on the left of the panel indicates the associated vessel diameters. The smallest capillaries are depicted in red and the largest vessels in blue. (J–N) The mean vessel volume fraction, vessel thickness, segment density, bifurcation density, and segment length were relatively lower in the thoracic region than the cervical and lumbar spinal cord; * p < 0.05. (O) Vessel distribution histogram revealed the vessel thickness in the thoracic region with a diameter of less than 25 μm was slightly lower than that of the cervical and lumbar regions. C, cervical spinal cord; T, thoracic spinal cord; L, lumbar spinal cord. * p < 0.05. Scale bar = 200 μm.

Journal: Frontiers in Neuroanatomy

Article Title: 3D Digital Anatomic Angioarchitecture of the Rat Spinal Cord: A Synchrotron Radiation Micro-CT Study

doi: 10.3389/fnana.2020.00041

Figure Lengend Snippet: Overview and quantification of the 3D morphology of the rat spinal cord microvasculature. (A–C) The raw image of the spinal cord microvasculature among cervical, thoracic, and lumbar regions. (D–F) Representative images of the segmented vasculature and the color-coded labeled vessels of the spinal cord among the three regions. The major arteries and veins including the posterior spinal artery (PSA), central sulcus artery (CSA), anterior spinal artery (ASA), and the posterior spinal vein (PSV). (G–I) The pseudocolored image of the spinal cord microvasculature among three regions. The color bar on the left of the panel indicates the associated vessel diameters. The smallest capillaries are depicted in red and the largest vessels in blue. (J–N) The mean vessel volume fraction, vessel thickness, segment density, bifurcation density, and segment length were relatively lower in the thoracic region than the cervical and lumbar spinal cord; * p < 0.05. (O) Vessel distribution histogram revealed the vessel thickness in the thoracic region with a diameter of less than 25 μm was slightly lower than that of the cervical and lumbar regions. C, cervical spinal cord; T, thoracic spinal cord; L, lumbar spinal cord. * p < 0.05. Scale bar = 200 μm.

Article Snippet: After the vasculature was segmented from the spinal cord parenchyma with Image Pro Analyser 3D software (Version 7.0, Media Cybernetics Inc., USA) based on the iterative gray-level threshold algorithm (Reichold et al., ), we performed the following protocol for the calculation of the 3D vascular morphological parameters (Kim et al., ). (1) Vectorization, skeletonization based on the voxel erosion (Lang et al., ) plugin in Image Pro Analyser 3D software, was used to automatically extract the centerline of the vessel tree ( ). (2) Once the centerline was extracted, numerous vascular quantification parameters such as vessel segment numbers, vessel segment density, vessel segment length, etc could be systematically analyzed and robustly quantified for complex vessel structure. defined the schema of vessel tree parameters.

Techniques: Labeling

Representative 3D printed model of the rat spinal cord microvasculature. (A,C) The spinal cord vasculature template obtained from SRμCT for different perspectives. (B,D) The corresponding 3D printed spinal cord vasculature model shows the complex interweaving of vessel branches. ASA, anterior spinal arteries; CSA, central sulcus arteries. (A,C) Scale bar = 200 μm; (B,D) scale bar = 5 cm.

Journal: Frontiers in Neuroanatomy

Article Title: 3D Digital Anatomic Angioarchitecture of the Rat Spinal Cord: A Synchrotron Radiation Micro-CT Study

doi: 10.3389/fnana.2020.00041

Figure Lengend Snippet: Representative 3D printed model of the rat spinal cord microvasculature. (A,C) The spinal cord vasculature template obtained from SRμCT for different perspectives. (B,D) The corresponding 3D printed spinal cord vasculature model shows the complex interweaving of vessel branches. ASA, anterior spinal arteries; CSA, central sulcus arteries. (A,C) Scale bar = 200 μm; (B,D) scale bar = 5 cm.

Article Snippet: After the vasculature was segmented from the spinal cord parenchyma with Image Pro Analyser 3D software (Version 7.0, Media Cybernetics Inc., USA) based on the iterative gray-level threshold algorithm (Reichold et al., ), we performed the following protocol for the calculation of the 3D vascular morphological parameters (Kim et al., ). (1) Vectorization, skeletonization based on the voxel erosion (Lang et al., ) plugin in Image Pro Analyser 3D software, was used to automatically extract the centerline of the vessel tree ( ). (2) Once the centerline was extracted, numerous vascular quantification parameters such as vessel segment numbers, vessel segment density, vessel segment length, etc could be systematically analyzed and robustly quantified for complex vessel structure. defined the schema of vessel tree parameters.

Techniques:

Schematic depiction of a randomly selected vessel within the intact spinal cord for 3D quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The corresponding 2D virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.

Journal: Frontiers in Neuroanatomy

Article Title: 3D Digital Anatomic Angioarchitecture of the Rat Spinal Cord: A Synchrotron Radiation Micro-CT Study

doi: 10.3389/fnana.2020.00041

Figure Lengend Snippet: Schematic depiction of a randomly selected vessel within the intact spinal cord for 3D quantitative measurement. (A) The 3D view of the one typical vessel within the intact spinal cord. (B) The corresponding 2D virtual section selected from panel (A) . (C–F) The vessel measurement from horizontal and vertical views. (G) Vessel tree displaying the parameters used for the 3D quantification of the networks of vessel branches characterized by their length L , diameter D , and bifurcation points. (H) The centerline skeleton of the vessel tree.

Article Snippet: A series of 2D slices were reconstructed using Image Pro Analyser 3D software (Version 7.0, Media Cybernetics, Inc., USA) to generate the 3D images.

Techniques: